Instrumentaton


Type-K Workhorse

Thermometer

The new Type-K Workhorse thermometer from Control Co, Friendswood, Tex, provides a sharp readout in dim and bright light, accuracy, temperature range, and a new chip design for lower cost. It maintains battery life for 150 to 200 continuous hours, Type-K range is -58.0 to 2372°F and -50.0 to 1300°C. Resolution is 0.1° between -50.0 to 200.0 and 1° elsewhere. Meter accuracy is ±(1°C + .75%) between 0 to 500°C; ± (1°C + 1%) 500 to 750°C; ±(1°C + 2%) 750 to 1000°C; ±(3°C + 4%) 1000 to 1200°C; ±2°C at -20; ±3°C at -40; ±4°C at -50. The recessed front panel adjustable offset allows users to adjust the thermometer to a specific temperature, an in-house calibration, or a particular sensor for increased accuracy. The hold button freezes the display to capture a current reading. It is compatible with all type-K probes. An individually serial-numbered traceable certificate is provided from the company's ISO 17025 calibration lab, accredited by A2LA. It indicates traceability to standards provided by the National Institute of Standards and Technology. A fast-response Type-K probe, bench stand, 9-volt battery, and carrying case are included. The probe diameter is ⅛ inch, the stem length is 3⅛ inches, the overall length is 5 inches, and the cable length is 40 inches. It measures 2 inches x 5 inches x 1¼ inches, and weighs 6 ounces.

Control Co
(281) 482-1714
www.control3.com



ABL80 FLEX

Portable STAT analyzer

The ABL80 FLEX from Radiometer America Inc, Westlake, Ohio, delivers accuracy, stability, and interference-free glucose performance in a portable STAT analyzer. The glucose sensor demonstrates a wide measuring range (0-75 mmol/L) and linearity. Sensor cassettes require no special handling, and can be stored at room temperature. The glucose sensor demonstrates noninterference (< |0.1| mmol/L) from common therapeutic substances.

Radiometer America Inc
(800) 736-0600, ext 333
www.radiometeramerica.com



WDR-3

Web data logger

TandD Corp, Saratoga Springs, NY, offers the new WDR-3, a network-compatible data logger that records output voltage and on/off (point of contact) signals from various types of sensors and measuring devices. Compatible with both analog and digital signal inputs, the logger—with its network connection—allows users to download measurements and data. It has a built-in network connection function that allows users to connect to all types of networks, including the Internet, for monitoring of real-time measurements. The product provides cost-effective means to monitor measurement signals in real time over long distances. The logger is useful for instrumentation such as flow meters, wattmeters, or analyzers, and for collecting recorded data of analyzers for environmental and weather data such as acid rain, pH, rainfall, snow accumulation, solar radiation, and wind speed/direction. The device allows data to be viewed, configured, and downloaded from a standard browser with access by LAN or Internet. An optional 802.11b adapter card is available for wireless access. Over-limit warnings can be obtained by e-mail or cell phone.

TandD Corp
(518) 669-9227
www.tandd.com



DH-40i

Microincubation chamber

The new DH-40i microincubation chamber from Warner Instruments, Hamden, Conn, is designed for imaging live cells at the required temperature and atmospheric conditions. This versatile chamber is useful for a variety of applications, such as high-resolution image analysis, fluorescence microscopy, and time-lapse imaging studies. Designed for the Warner Instruments RC-40 quick change imaging chambers and 35-mm culture dishes, the device can be adapted for use with most 35-mm Petri dishes. It accommodates upright and inverted microscopes, and features an optional heated-top cover slip to eliminate condensation when used as a closed system.

Warner Instruments
(800) 599-4203
www.warnerinstruments.com



Related Articles - Product News

Automation - March 2008

Computers/IT - March 2008

Instrumentation - March 2008

Testing/Diagnostics - March 2008

Computers/IT - February 2008

Displaying 5 of 79 related articles. View all related articles.


Article Tools
Email This Article
Reprint This Article
Write the Editor
Resources
Media Kit
Editorial Advisory Board
Advertiser Index
Reprints
News | Current Issue | Buyer's Guide | Archives | Calendar | Resources | Careers
About CLP | Contact Us | Subscribe | Read Weekly eNewsletter
Media Kit | Editorial Advisory Board | Advertiser Index | Reprints
Allied Healthcare
24X7 |  Chiropractic Products Magazine |  Clinical Lab Products (CLP) |  Orthodontic Products |  The Hearing Review
Hearing Products Report (HPR) |  HME Today |  Rehab Management |  Physical Therapy Products |  Plastic Surgery Products
Imaging Economics |  Medical Imaging |  RT |  Sleep Review
Medical Education
SynerMed Communications |  IMED Communications
Practice Growth
Practice Builders
Copyright © 2008 Ascend Media LLC | CLINICAL LAB PRODUCTS | All Rights Reserved. Privacy Policy | Terms of Service